Light curtains
Remote light curtains
SPACEGUARD ™ SERIES
SG 11
- 5 m sensitivity
- 16 to 64 parallel beams
- Distance between beams 28 or 56 mm
- Active height from 425 mm to 1770 mm
- Detector length from 570 mm to 2105 mm
- Flexible cable
- Connector to the controller
- Thin line (10×28 mm) or leading edge (37.5×13 mm) of the detector housing
- Power indicator
- Static and dynamic applications
SGC 11
- 5 m sensitivity
- 230 V AC, 115 V AC or 24 V AC – all with a supply voltage of 24 V DC
- Manual and automatic adjustment sensitivity
- Automatic detector test
- 1 relay and / or 1 transistor output
- Toggle selectable light or dark function
- Switch to select the far or short range
- Selectable buzzer switch
- Selectable timeout function
- Power, output, alarm, standby time and
- detector malfunction indicators
- Alarm and timeout output
- Detector connection connector
Autonomous light curtains
SPACEGUARD ™ SERIES
SG 1
- Measuring range 0-4 m
- From 34 to 194 transverse scanning beams
- Active height from 650 mm to 1800 mm
- Detector length 850 to 2100 mm
- Flexible cable connection
- Automatic sensitivity adjustment
- Thin line (10×28 mm), leading edge (37.5×13 mm) or waterproof thin sensor (12×30 mm)
- Power, output and signal status indicators
- Power supply 12-36 V DC
- 5-wire, solid-state relay output
- Test input
- Timeout function via wired connection
- Static and dynamic applications
SG 2
- Measuring range 0-4 m
- 94 cross scanning beams
- Active height 1800 mm
- Detector length 2000 mm or 2100 mm
- Flexible cable connection
- Automatic sensitivity adjustment
- Slim housing (10×28 mm) detector housing
- Power, output and signal status indicators
- Power supply 12 – 36 V DC
- Quenching function up to 10 channels
- 5-wire, solid-state relay output
- Test input
- Light / Dark function via wired connection
SG 10
- Sensitivity range 1-10 m
- From 34 to 274 transverse scanning beams
- Active height from 650 mm to 2535 mm
- Detector length from 850 mm to 2800 mm
- Cable or plug connection
- Automatic sensitivity adjustment
- Waterproof thin housing (12×30 mm)
- Power indicators , Output, and Signal Status
- Power Supply 12 – 36 V DC
- 5-wire, Solid State Relay Output
- Test Input
- Function light / darkness through a wired connection
SG 14
- Sensitivity range 1-10 meters
- From 16 to 56 parallel beams
- Active height from 695 mm to 2535 mm
- Detector length from 850 mm to 2800 mm
- Cable or plug connection
- Automatic sensitivity adjustment
- Water-resistant thin line (12×30 mm) or leading edge
- ( 38.4×14 mm) or detector housing
- Power, output and signal status indicators
- Supply voltage 12 – 36 V DC
- 5-wire, solid state relay output
- Test input